Air Cooled Water Chillers |
Design-caused extraordinarily small system volumes result in the comparison to the achievement.From this minimum refrigerant fillings and if necessary substantial savings with condition result and equipment of the engine rooms.
DDC regulation with the possibility for the combination on superordinate Monitoring systems, remote maintenance possible.Scrollverdichter with 1 - 4 performance levels, for the connection to external condensers,Evaporator with thermalstatic Einspritzventil, all heat exchangers as disk heat more tauscher in hardsoldered or full-welded building method, integrated circulation pumps.
Rotary screw compressor constantly regularly, for the connection to external condensers,Evaporator with electronic Einspritzventil, all heat exchangers as disk heat more tauscher in hardsoldered or full-welded building method, integrated circulation pumps. |
Water Chiller (For placing inside)
We can provide water chillers for placing inside. The advantage for placing a water chiller inside is, that a using of a anti freezing medium (glycol) isn’t necessary. Further more by choosing a water chiller for placing inside it is movable and flexible instead of a fixed placed water chiller outside. |

|
 |
 |
Water Chiller (For placing outside)
We can provide water chillers for placing outside. The advantage for placing a water outside to contain solutions with a long distance between water chiller and SideCooler®. Also created for a version without a space for placing a water chiller inside.
|
Indoor Chiller
Packaged air-cooled water chillers and with centrifugal fans. Range with hermetic
Scroll compressors and R410a refrigerant gas.
Compressor: hermetic. rotary Scroll compressor,Complete with thermal protection.
Water side heat exchanger: adequately insulated Stainless steel plate exchanger, complete with antifreeze
heater and water flow differential pressure switch.
|
|
|
 |
 |
Datasheet 15.2 KW |
 |
811 KB |
 |
101 KB |
 |
Datasheet 30 KW |
 |
468 KB |
 |
699 KB |
 |
Datasheet 50 KW |
 |
68 KB |
 |
699 KB |
| |
| Install the below plugins if you don't have for a greater experience. PDF Reader |
| |
|
Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille.
Fan:centrifugal electric fans with directly coupled motor, fitted with internal thermal protection and protection grilles.
Control: microprocessor electronic control available in 2
versions: standard, with AdaptiveFunction logic,
|
Outoor Chiller
BRACH + MOLL water chiller
Unit Frame
Modular self-supporting frame in galvanised sheet steel with baked-on polyester powder coating (colour RAL 5014) and threaded fasteners in stainless steel.
Compressors:
Hermetic scroll compressors connected in parallel (tandem or trio configuration).Equipped with crankcase heater, thermal protection, liquid line sight glass, contactors and oil equalisation line.
Refrigerant Circuit:
The circuit includes: liquid line shut-off valve, charge connection, liquid line sight glass, filter dryer,
electronic expansion valve, safety valve, pressure transducers to relay information on high and low
pressure values and relative condensing and evaporating temperatures for display on the controller, high and low pressure switches. |
 |
|
 |
Datasheet - Technical |
 |
3.31 MB |
 |
3.25 MB |
 |
Datasheet - Global Water Chiller |
 |
48.6 KB |
 |
40.7 KB |
| |
| Install the below plugins if you don't have for a greater experience. |
| PDF Reader |
|
Evaporator:
Brazed plate and mechanical flow switch (supplied installed).
Condenser:
Composed of high efficiency coils with "V" execution..
Fans: Axial fan directly coupled to 6-pole motors, thermal overload protection and safety guard
Electrical Panel:With main switch, power and control circuit protection, and fan contactors. Microprocessor control
with function display.
Testing:
Units are factory-tested and shipped complete with refrigerant charge and oil.
|
Main Accessories:
 |
Condensing pressure control with fan speed regulator; |
 |
Kit for low water temperatures; |
 |
RS485 serial interface supporting Carel, Modbus, (Echelon and Bacnet protocols; |
| |
combinable also with Johnson and Trend supervision) (from 20.3 to 93.12);. |
 |
Power factor correction cos_ >= 0,9; |
 |
Remote user terminal panel (in addition to the on-board terminal); |
 |
Variable set point with remote signal (0- 1V, 0-10V, 0-20mA, 4-20mA)(from 20.3 to 93.12); |
 |
Coils with special anti-corrosion treatment; |
 |
Rubber or spring type anti-vibration mounts; |
 |
Non-standard RAL paint colours. |
|
|