UPS & Battery Banks:
Offering robust, reliable and clean flow of power to the Data Center and mission critical systems, TechXact delivers sophisticated UPS systems and varied types of battery banks that accommodate full redundancy, downtime free maintenance, remote and local manageability, modular expandability and to sustain power availability as per scoped requirements of high-availability data centers.
|
The general categories of modern UPS systems are on-line, line-interactive, and standby. An on-line UPS uses a "double conversion" method of accepting AC input, rectifying to DC for passing through the battery (or battery strings), then inverting back to AC for powering the protected equipment. A line-interactive UPS maintains the inverter in line and redirects the battery's DC current path from the normal charging mode to supplying current when power is lost. In a standby ("off-line") system the load is powered directly by the input power and the backup power circuitry is only invoked when the utility power fails. Most UPS below 1 kVA are of the line-interactive or standby variety which are usually less expensive.
For large power units, Dynamic Uninterruptible Power Supply are sometimes used. A synchronous motor/alternator is connected on the mains via a choke. Energy is stored in a flywheel. When the mains power fails, an Eddy-current regulation maintains the power on the load. DUPS are sometimes combined or integrated with a diesel-generator forming a diesel rotary uninterruptible power supply, or DRUPS. |
 |
 |
A Fuel cell UPS have been developed in recent years using hydrogen and a fuel cell as a power source, potentially providing long run times in a small space.
An Uninterruptible Power Supply (UPS) only has one mission, to provides battery backup when the electrical power fails or drops to an unacceptable voltage level. Small UPS systems provide power for a few minutes; enough to power down the computer in an orderly manner, while larger systems have enough battery for several hours. In mission critical datacenters, UPS systems are used for just a few minutes until electrical generators take over.
There are various classifications of UPS that has been established by the European Norm (EN50091-3/IEC62040-3) which most of the designers and people who are in the field of data Center do not consider in selection of UPS Class. |
UPS Classification (EN50091-3/IEC62040-3):
VFD-Class (Voltage and Frequency Dependent)
Off-Line topology (also called stand-by) is a cost-effective UPS choice for small, less critical, stand-alone applications such as isolated PLC, PCs and peripherals. Network communications are a useful option.
The Offline / Standby UPS (SPS) offers only the most basic features, providing surge protection and battery backup. Usually the Standby UPS offers no battery capacity monitoring or self-test capability, making it the least reliable type of UPS since it could fail at any moment without warning. These are also the least expensive,. The SPS may be worse than using nothing at all, because it gives the user a false sense of security of being assured protection that may not work when needed the most.
|
 |
 |
With this type of UPS, a user's equipment is normally connected directly to incoming utility power with the same voltage transient clamping devices used in a common surge protected plug strip connected across the power line. When the incoming utility voltage falls below a predetermined level the SPS turns on its internal DC-AC inverter circuitry, which is powered from an internal storage battery.
The SPS then mechanically switches the connected equipment on to its DC-AC inverter output. The switchover time is stated by most manufacturers as being less than 4 milliseconds, but typically can be as long as 25 milliseconds depending on the amount of time it takes the Standby UPS to detect the lost utility voltage: |
VI-Class (Voltage Independent)
Line-Interactive topology provides highly effective power conditioning plus battery back-up. This is particularly applicable in areas where power outages are rare, but where there are frequent power fluctuations. Network communications are available and sometimes necessary.
The Line-Interactive UPS is similar in operation to a Standby UPS, but with the addition of a multi-tap variable-voltage autotransformer. This is a special type of electrical transformer that can add or subtract powered coils of wire, thereby increasing or decreasing the magnetic field and the output voltage of the transformer.
|
 |
 |
This type of UPS is able to tolerate continuous undervoltage brownouts and overvoltage surges without consuming the limited reserve battery power. It instead compensates by auto-selecting different power taps on the autotransformer. Changing the autotransformer tap can cause a very brief output power disruption, so the UPS may chirp for a moment, as it briefly switches to battery before changing the selected power tap.
Autotransformers can be engineered to cover a wide range of varying input voltages, but this also increases the number of taps and the size, weight, complexity, and expense of the UPS. It is common for the autotransformer to only cover a range from about 90v to 140v for 120v power, and then switch to battery if the voltage goes much higher or lower than that range. |
In low-voltage conditions the UPS will use more current than normal so it may need a higher current circuit than a normal device. For example to power a 1000 watt device at 120 volts, the UPS will draw 8.32 amps. If a brownout occurs and the voltage drops to 100 volts, the UPS will draw 10 amps to compensate. This also works in reverse, so that in an overvoltage condition, the UPS will need fewer amps of current.
VFI-Class (Voltage & Frequency Independent):
The True On-Line Double Conversion this topology is accomplished with double conversion technology. Network communications are often necessary to protect mission-critical applications.
The Online UPS is ideal for environments where electrical isolation is necessary or for equipment that is very sensitive to power fluctuations. Although once previously reserved for very large installations of 10kW or more, advances in technology have permitted it to now be available as a common consumer device, supplying 500 watts or less. The Online UPS is generally more expensive but may be necessary when the power environment is "noisy" such as in industrial settings, for larger equipment loads like data centers, or when operation from an extended-run backup generator is necessary.
The basic technology of the online UPS is the same as in a Standby or Line-Interactive UPS. However it typically costs much more, due to it having a much greater current AC-to-DC battery-charger/rectifier, and with the rectifier and inverter designed to run continuously with improved cooling systems. It is called a Double-Conversion UPS due to the rectifier directly driving the inverter, even when powered from normal AC current.
In an Online UPS, the batteries are always connected to the inverter, so that no power transfer switches are necessary. When power loss occurs, the rectifier simply drops out of the circuit and the batteries keep the power steady and unchanged. When power is restored, the rectifier resumes carrying most of the load and begins charging the batteries, though the charging current may be limited to prevent the high-power rectifier from overheating the batteries and boiling off the electrolyte.
The main advantage to the on-line UPS is its ability to provide an electrical firewall between the incoming utility power and sensitive electronic equipment. While the Standby and Line-Interactive UPS merely filter the input utility power, the Double-Conversion UPS provides a layer of insulation from power quality problems. It allows control of output voltage and frequency regardless of input voltage and frequency. |
 |
|
|